Thermocouples for DIN EN 14597 Tested Devices and Plants (901006)
Thermocouples for DIN EN 14597 Tested Devices and Plants (901006) China RoHS-20 DIN

  • For heat conducting systems according to DIN 4754
  • For temperatures up to 1500 °C
  • Available as single or double thermocouples
  • For operating media water, oil, or air
  • For tested control and limitation devices

Screw-In Thermocouples with Terminal Head Form B (901020)
Screw-In Thermocouples with Terminal Head Form B (901020) China RoHS-20 Metrological certification

  • For temperatures from -200 to +800 °C
  • Available with different thermocouples
  • As single or double thermocouple
  • Terminal head form B, BUZ, BUZH, BBK
  • Available with transmitter

Screw-In Thermocouples with Form J Terminal Head (901030)
Screw-In Thermocouples with Form J Terminal Head (901030) China RoHS-20 Metrological certification

  • For temperatures from -200 to +800 °C
  • As single or double thermocouple
  • Assembly insulated or connected with protection tube
  • Protection type IP65

Screw-In Thermocouples with Compensating Cable (901050)
Screw-In Thermocouples with Compensating Cable (901050) Metrological certification China RoHS-e

  • For temperatures from -200 to +600 °C
  • Available with different thermocouples
  • As single or double thermocouple
  • Compensating cable made of silicon or metal braiding

Screw-In Melt Thermocouple (901090)
Screw-In Melt Thermocouple (901090) China RoHS-e

  • For temperatures from -40 and +600 °C
  • Available with different thermocouples
  • Protection tube and probe tip out of stainless steel
  • Structure insulated or connected with probe tip
  • Ceramic insulated probe tip
  • For application in the plastics industry

Push-in Thermocouple with Form A Terminal Head (901110)
Push-in Thermocouple with Form A Terminal Head (901110) China RoHS-20 Metrological certification

  • For temperatures between -200 and +1600 °C
  • With protection tubes made of various materials
  • As single and double thermocouple
  • Available with transmitter

Push-In Thermocouple with Form B Terminal Head (901120)
Push-In Thermocouple with Form B Terminal Head (901120) China RoHS-20 Metrological certification

  • For temperatures from -200 to +1600 °C
  • With protection tubes made from various materials
  • As single or double thermocouple
  • Terminal head form B, BUZ, BUZH, BBK
  • Available with transmitter

Push-In Thermocouple with Compensating Cable (901150)
Push-In Thermocouple with Compensating Cable (901150) China RoHS-e

  • For temperatures from 50 to 600 °C
  • Available with different thermocouples
  • With protection tube made of stainless steel
  • Compensating cable made of silicon or metal braiding
  • Also with 90° cable outlet

Push-In Thermocouple with Bayonet Connection (901190)
Push-In Thermocouple with Bayonet Connection (901190) China RoHS-20

  • For temperatures from 0 to 400 °C / 32 to 750 °F
  • As single or double thermocouple
  • Good heat transfer through adjustable spring pressure
  • Insulated assembly or connected with protection tube
  • Installation and removal without tools

Mineral-Insulated Thermocouple with Bare Connection Wires According to DIN 43710 and DIN EN 60584 (901210)
Mineral-Insulated Thermocouple with Bare Connection Wires According to DIN 43710 and DIN EN 60584 (901210) Metrological certification China RoHS-e

  • For temperatures from -200 to +1200 °C
  • Flexible sheath cable with vibration-resistant measuring insert
  • Protection tube diameter as of 1.0 mm
  • Quick response time
  • Application-specific insertion length

Mineral-Insulated Thermocouples with Form B Terminal Head According to DIN 43710 and DIN EN 60584 (901210)
Mineral-Insulated Thermocouples with Form B Terminal Head According to DIN 43710 and DIN EN 60584 (901210) China RoHS-20

  • For temperatures from -200 to +1200 °C
  • Flexible sheath cable with vibration-resistant measuring insert
  • Protection tube diameter as of 3.0 mm
  • Quick response time
  • Application-specific insertion length

Mineral-Insulated Thermocouples with Form J Terminal Head According to DIN 43710 and DIN EN 60584 (901210)
Mineral-Insulated Thermocouples with Form J Terminal Head According to DIN 43710 and DIN EN 60584 (901210) China RoHS-20 Metrological certification

  • For temperatures from -200 to +1200 °C
  • Flexible sheath cable with vibration-resistant measuring insert
  • Protection tube diameter as of 3.0 mm
  • Quick response time
  • Application-specific insertion length

Mineral-Insulated Thermocouples with Standard Tab Connector According to DIN 43710 and DIN EN 60584 (901210)
Mineral-Insulated Thermocouples with Standard Tab Connector According to DIN 43710 and DIN EN 60584 (901210) Metrological certification China RoHS-e

  • For temperatures from -200 to +1200 °C
  • Flexible sheath cable with vibration-resistant measuring insert
  • Protection tube diameter as of 0.5 mm
  • Quick response time
  • Application-specific insertion length

Mineral-Insulated Thermocouple with Compensating Cable According to DIN 43710 and DIN EN 60584 (901210)
Mineral-Insulated Thermocouple with Compensating Cable According to DIN 43710 and DIN EN 60584 (901210) Metrological certification China RoHS-e

  • For temperatures from -200 to +1200 °C
  • Flexible sheath cable with vibration-resistant measuring insert
  • Protection tube diameter as of 0.5 mm
  • Quick response time
  • Application-specific insertion length

JUMO FOODtemp Insertion Thermocouple (901350)
JUMO FOODtemp Insertion Thermocouple (901350) China RoHS-e

  • For temperatures between -100 to +260 °C
  • Steam-tight
  • High mechanical strength
  • For use in the food industry
  • Available with multiple measuring points